mgh006 8 360/0.476 1626197 mgh006.dat 212 1185(-48)/mV 12 0 -645 42598 0 ECG lead I mgh006.dat 212 1185(50)/mV 12 0 -854 2014 0 ECG lead II mgh006.dat 212 1185(102)/mV 12 0 -868 56214 0 ECG lead V mgh006.dat 212 11.91(-1227)/mmHg 12 0 -1528 59788 0 ART mgh006.dat 212 20.26(-991)/mmHg 12 0 -1349 64864 0 PAP mgh006.dat 212 20.06(-1007)/mmHg 12 0 -1431 12606 0 CVP mgh006.dat 212 1000 12 0 -985 37349 0 Resp. Imp. mgh006.dat 212 1000 12 0 182 60721 0 CO2 #: 72 : M : Endocarditis; Sepsis # PHARMACOLOGIC SUPPORT: # Dopamine @ 950 mcg/min # ELECTROCARDIOGRAPHIC DATA: # UNDERLYING RHYTHM: # Ventricular pacing @ 100 bpm for sinus rhythm with A-V dissociation # PACEMAKER INFORMATION: # Temporary ventricular fixed rate pacing (VOO) # Transvenous wires (USCI bipolar #4) # Medtronic generator (output 5 mv) # Non-functional permanent coplin lithium pacer # TECHNICAL COMMENTS: # Pacer mode (CH2) activated @ 22 min # Persistent ECG interference # HEMODYNAMIC DATA: # ART: 120/50 MEAN: 72 # PAP: 47/20 PCW: 17(@ 20 min, 32 min, 39 min) # RAP: 11 # WAVEFORM PATTERNS: # Intermittent cannon waves in CVP and PCW due to A-V asynchrony # TECHNICAL COMMENTS: # CVP transduced with medications infusing simultaneously via pump # CVP on without medications @ 9 min - 11 min # Simultaneous CVP and PCW recording @ 20 min # RESPIRATORY DATA: # RATE: 8/22 bpm # MODE OF VENTILATION: # Intermittent mandatory ventilation # CO2 RECORDING: # Datex sidestream sensor # CO2 monitor malfunction @ 36 min, turned off