mgh070 8 360/0.476 1682047 17:55:40 10/12/1992 mgh070.dat 212 282(-372)/mV 12 0 -29 13949 0 I mgh070.dat 212 199(-2)/mV 12 0 13 23500 0 II mgh070.dat 212 247(-25)/mV 12 0 38 15199 0 V mgh070.dat 212 11.63(-1243)/mmHg 12 0 224 21505 0 ART mgh070.dat 212 20.44(-1241)/mmHg 12 0 2047 22040 0 PAP mgh070.dat 212 19.26(-1337)/mmHg 12 0 -1120 15782 0 CVP mgh070.dat 212 1000 12 0 -413 -30833 0 Resp. Imp. mgh070.dat 212 1000 12 0 -918 8243 0 CO2 #: 81 : M : Resection and grafting of abdominal aortic aneurysm # PERTINENT HISTORY: # Coronary disease # Aortic stenosis # Cardiomyopathy # PHARMACOLOGIC SUPPORT: # Digoxin @ 32 min # ELECTROCARDIOGRAPHIC DATA: # UNDERLYING RHYTHM: # A trial fibrillation @ 120 bpm # RHYTHM DISTURBANCES: # Ventricular pacing overdrive for ventricular ectopy # PACEMAKER INFO: # Specifics unavailable # TECHNICAL COMMENTS: # RA electrode off @ 54 min # HEMODYNAMIC DATA: # ART: 120/60 MEAN: 68 # PAP: 54/24 PCW: 22 (@ 10 min, 13 min, 27 min) # RAP: 12 # WAVEFORM PATTERNS: # Atrial contours changing? V waves # Pulmonary hypertension # RESPIRATORY DATA: # RATE: 16 bpm # MODE OF VENTILATION: # Spontaneous