mgh071 8 360/0.476 1771200 19:04:21 10/12/1992 mgh071.dat 212 246(-57)/mV 12 0 22 -155 0 ECG lead I mgh071.dat 212 268(-22)/mV 12 0 23 -23803 0 ECG lead II mgh071.dat 212 201(21)/mV 12 0 47 5338 0 ECG lead V mgh071.dat 212 11.95(-1326)/mmHg 12 0 29 8327 0 ART mgh071.dat 212 1000 12 0 2047 -1728 0 PAP mgh071.dat 212 1000 12 0 -1019 -28051 0 CVP mgh071.dat 212 1000 12 0 58 23300 0 Resp. Imp. mgh071.dat 212 1000 12 0 1042 10228 0 CO2 #: 79 : F : Fixation hip fracture; GI bleed # PERTINENT HISTORY: # Post mitral valve replacement # Aortic regurgitation # PHARMACOLOGIC SUPPORT: # Dopamine @ 80 mcg/min started @ 53 min # ELECTROCARDIOGRAPHIC DATA: # UNDERLYING RHYTHM: # Ventricular pacing @ 70 bpm for sick sinus syndrome with AV block # PACEMAKER INFO: # Permanent ventricular demand pacemaker (WI) # Medtronic Spectrax 5985 # TECHNICAL COMMENTS: # Agitated # HEMODYNAMIC DATA: # ART: 118/45 # PAP: 90/28 PCW: 20 (@ 3 min, 8 min, 22 min) # RAP: 20 CO: 3.2 # WAVEFORM INTERPRETATION: # Respiratory variation # TECHNICAL COMMENTS: # PA/CVP on same transducer # CVP on @ 14 min and 37 min - 41 min # Zero/cal/pop-test sequence @ 27 min # RESPIRATORY DATA: # RATE: 22 bpm # MODE OF VENTILATION: # Spontaneous